1100W BSWF





User Manual
Please read the instructions carefully
Chapter 1 Notes and Installation
1.Maintenance
This luminaire should be kept dry and avoid working in wet conditions.
Intermittent use can effectively extend the life of this lamp.
In order to obtain good ventilation and lighting effects, pay attention to frequently clean the fan and fan network as well as lenses.
Do not use organic solvents such as alcohol to rub the lamp housing to avoid damage.
2.statement
This product in the factory, the performance is good, packaging complete. All users shall strictly comply with the warnings and operating instructions stated above, any damage caused by misuse is not covered by the Company's warranty, and failures and problems caused by neglect of the operating manual are not the responsibility of the dealer.
This manual is subject to technical changes without notice.
3.Technical parameters
Light :
power rating:
colour temperature :
color rendering index, rendering index:
luminous flux:
Signal interface: Three-pin card socket
Control methods: DMX512, RDM
Channel Mode: 35 international standard DMX512 channels
Display System: LCD screen with Chinese-English language switching capability
Fixed colors: 5 colors + white light
Color mixing system: Independent CMY color mixing system
Color temperature adjustment: Independent CTO 2800–6000K linear adjustment
Prism Disk: The independent 8-prism can rotate both clockwise and counterclockwise.
Effects Panel: Features stunning simulated dynamic effects such as flickering flames and flowing wate
Fixed patterns: 6 fixed pattern pieces + white circle
Rotating glass pattern: 7 modular pattern pieces (removable) + white circular piece
Cutting system: 4 independent cutting blades; each blade can be independently shut off from light and can rotate 90°.
Nebulization System: Independent 0–100% linear nebulization system
Four-in-one optical lens design: (BEAM beam mode): 2–6; (SPOT spot pattern mode): 10–48
0–52. The four modes can be switched freely, enabling a "four-in-one" function for beam shaping, staining, pattern generation, and cutting.
Dimming system: 0–100% linear adjustment
Dimming frequency: adjustable from 1200Hz to 2400Hz; ensures no flickering when capturing with a 4K camera.
Horizontal scanning: 540 (16-bit resolution scanning) 
  4.Product considerations
To ensure the service life of the product, do not place the product in wet or leaky places, let alone work in environments above 60 degrees
Do not place the appliance in a loose or vibrating place.
To avoid the risk of electric shock, a repair request for this product is made to assist a professional.
When the lamp is used, the supply voltage change should not exceed10%of the±, the voltage is too high, will shorten the life of the bulb, the voltage is too low, it affects the light color of the bulb. 
After the power is off, it takes 20 minutes to cool down sufficiently with the lamp before it can be powered on again. 
To ensure the normal use of this product, please read this instruction carefully. Signal line connection(DMX).
Use A Compliant RS-485 Cable: Shielded,120ohm Characteristic Impedance,22-24 AWG,LowTolerance. Do not use microphone cables or cables with different specified characteristics. The terminals must be connected using a 3- or 5-pin  XLR male/female  connector. (Minimum 1 / 4 W). 
Important: Lines cannot come into contact with each other or with metal housings.

Figure  SEQ 图_ \* ARABIC 1  DMX signal line connection diagram
5.Lamp installation
Lamps can be placed horizontally, angled and upside down. Be sure to pay attention to the installation method when hanging and hanging upside down.
As shown in  REF _Ref386500717 \h Figure 2, before positioning the lamp, to ensure the stability of the installation site, when reversing the suspension installation, it is necessary to ensure that the lamp does not fall on the support frame, the need to use safety ropes through the support frame and lamp handle for auxiliary hanging to ensure safety,. Prevent lamps from falling and sliding. 
When the lamp is installed and commissioned, pedestrians are not allowed to pass below, and safety ropes are regularly checked for wear and hook screws are loose.
If the suspension installation is not stable, resulting in the fall of the lamp and all consequences, we do not assume any responsibility.

Figure  SEQ 图_ \* ARABIC 2  Hanging lighting graphics
Chapter 2 control panel
2.1 Key Instructions


Figure 3 Schematic diagram of key description on the panel
The following takes "Modify DMX address code" as an example to describe the use of keys:
1, if the current is not the main interface, press the "left" key (one or more times) to return to the main interface
2, in the main interface, press the "up" key or "down" key to select the "DMX Settings" button
3. Press the "OK" key to enter the "DMX Settings" interface
4, press the "up" key or "down" key to modify the DMX address code
5, press the "OK" key to exit the editing state
6. Press the right button on the main interface to enter the calibration interface shortcut key.
7. Note: The shortcut keys at the bottom of the main interface, Chinese/English, screen rollover and reset, can only be manually touched, not pressed.

  Figure the main menu diagram

2.2.1 DMX Settings
Key description: Press up or down is +1 or -1 mode;Press the right button is the next one;Press the left and confirm button to save and exit.
Manual instructions: Enter the hundreds place first, then the tens place, then the last place.(For example, to enter the 286 address code, click 2, then 8, and finally 6)

2.2.2  Menu
Main menu Secondary menuThree-level menuFour-level menuFive-level menuDMX Setup Dmx Address1 - 512Channel Mode 35CHRun Mode DMX Auto Sound Personality Pan InverseNoYes Tilt Inverse No Yes Tilt Feedback Off On Dimmer CurveLinear Square Law Inv SQ Law S-Curve LED Frequency 600Hz 1200Hz 2400Hz 4800Hz9600Hz12000Hz 24000HzNo Data ModeBlackoutHold M/S Mode Slave Master Sensitivity 10 - 100DisplayDisplay Rotate Normal Rotate 180Display Intensity 1-100Temperature Unit°C°FLanguageEnglish中文Motor ResetAllNo Yes Tilt No YesEffectNoYes Manual ControlPan 0 - 255。。。0 - 255Function 0 - 255DMX Live Pan 0 - 255。。。0 - 255Function 0 - 255ServicePassword CalibrationMotor Pan -128 -> 127。。。-128 -> 127Factory DefaultNo Yes Clear Power On TimeNo Yes Clear Lamp Hours No Yes Information Power On Time xxxxxH LED Hours xxxxxHSW Version 1U：Vx.x.x（display PCBA） 2U：Vx.x.x （Arm PCBA）RDM UID0xXXXX-XXXXXXXX
Chapter 3 Channel Description
9.Channel table
This luminaire channel can view the order in scene mode, which is set on the Address Settings page, as shown in the table below:
Channel table
channelfunctionChannel valueeffect35CH1Pan000-2550-100%2Tilt000-2550-100%3PanFine000-2550-100%4TiltFine000-2550-100%5PanTiltSpeed000-255Horizontal and vertical speed, from fast to slow6Strobe000-003close light004-103Pulsed flicker from slow to fast104-107Open light108-207Slow to fast gradual flicker208-212Open light213-251Random flicker from slow to fast252-255Open light7Dimmer000-255Dim from 0% to 100%8Cyan000-2550-100%9Magenta000-2550-100%10Yellow000-2550-100%11CTO000-2550-100%12Colour000-009white light010-019Color 1020-029Color2030-039Color3040-049Color4050-059Color5060-069Color5+Color4070-079Color4+Color3080-089Color3+Color2090-099Color2+Color1100-109Color1+white light110-255Slow to fast forward13CRI000-127acanthophysis128-255explicit insertion14FixGobo000-009white light010-019pattern1020-029pattern2030-039pattern3040-049pattern4050-059pattern5060069pattern6070-079pattern1Jitter from slow to fast080-089pattern2Jitter from slow to fast090-099pattern3Jitter from slow to fast100-109pattern4Jitter from slow to fast110-119pattern5Jitter from slow to fast120-129pattern6Jitter from slow to fast130-191Fast forward to slow192-255Reverse from slow to fast15RotGobo000-009white light010-019Rotate1020-029Rotate2030-039Rotate3040-049Rotate4050-059Rotate5060-069Rotate6070-079Rotate7080-089Rotate1Jitter from slow to fast090-099Rotate2Jitter from slow to fast100-109Rotate3Jitter from slow to fast110-119Rotate4Jitter from slow to fast120-129Rotate5Jitter from slow to fast130-139Rotate6Jitter from slow to fast140-149Rotate7Jitter from slow to fast150-190Fast forward to slow191-192Stop193-255Reverse from slow to fast16GoboRot000-127Angle adjustment128-190Pattern fast to slow191-192Stop193-255Pattern Inversion from Slow to Fast17Animation Disk000-009white light010-127linearity pattern128-255Slow to fast pattern jitter18Zoom000-2550-100%19Focus000-2550-100%20FocusFine000-2550-100%21Prism000-127No prism128-255Prism Cut-in22PrismRot000-127prism angle adjustment128-187The prism rotates from fast to slow188-195prism stop rotation196-255Prism reversal from slow to fast23Frost000-003NO Frost004-255Frost Cut-in24Framing Up1000-2550-100%25Framing Up2000-2550-100%26Framing Down1000-2550-100%27Framing Down2000-2550-100%28Framing Left1000-2550-100%29Framing Left2000-2550-100%30Framing Right1000-2550-100%31Framing Right2000-2550-100%32Framing Macro000-009nonfunction010-247Select shape248-255Auto Switch Graphics33Framing Rota000-2550-100%34Iris000-127linear aperture128-159fast in slow out160-191slow in, fast out192-255fast aperture in and out35Function210-215XY reset，hold 3S220-235head motor reset，hold 3S240-255reset all motors，hold 3S
Chapter 4 Common Faults and Precautions for Use
10.Common fault handling
Lamps contain microcomputer circuit boards, high-voltage power supply and other professional components, for your safety and product life, non-professionals should not remove lamps and related accessories without authorization.
1.The bulb is not lit (except forthe LED light source).
Possible causes: The bulb is not completely cooled, or the bulb has a lifetime, as follows:
Due to abnormal operation, the bulb is not completely cooled, should let the lamp body cool for more than 10 minutes, so that its interior fully restored to normal state, and then start the power supply again can be;
Check that the bulb has reached service life and replace it with a new one;
Check that the light bulb and the light-lighting line leak, fall off or come into poor contact;
Replace the new light-lighting machine.
2.The beam appears dim
Possible causes: Long use of light bulbs or dirty light paths, handled as follows:
Check that the bulb has reached service life and replace it with a new one;
Check that the optics or bulbs are clean, that dust is accumulated on the optics such as the bulbs, and that the bulbs and components in the lamps need to be cleaned and maintained regularly.
3.The pattern projection is blurry
Check that the electron focus channel value is appropriate for the current projection distance.
4.The lamps work intermittently
Reason: The internal line goes into a protected state and is handled as follows:
Check whether the fan is operating normally or dirty, resulting in an increase in the internal temperature of the lamp;
Check that the internal temperature control switch is closed;
Check that the bulb has reached service life and replace the new bulb.
5.The lamp does not accept the control of the console after a normal reset
Possible cause: signal line failure or incorrect luminaire parameter settings, handled as follows:
Check the starting address code and check the connection of the DMX signal cable (Whether the signal wire and cable are in good condition and the connection of the signal head is loose);
Add a signal amplifier, plus 120 ohm terminal resistors;
6.The lamp does not start
Can cause: poor power supply lines, handled as follows:
Check if the insurance on the power input socket is blown off and replace the insurance;
Lamps are in poor contact with the line due to vibration during long-distance transport
Check the input power supply, computer board, etc. for plug-in devices.
11.Precautions for use
Check whether the local power supply meets the product voltage rating requirements, leakage protectors, overcurrent protectors, etc. meet the load requirements;
Do not use a damaged power cord in the insulation and do not connect the power cord to other wires;
Lamps are used in strong wind cooling, easy to accumulate dust, must be cleaned once a month, especially the cooling air vents, otherwise it will be blocked by dust accumulation, resulting in poor heat dissipation, so that the lamp abnormal.
When installing lamps, the fixed screws must be tightened, and equipped with safety ropes, and timely inspection;
When the lamp is installed and positioned, any point on the surface of the lamp is associated with any flammable and explosive material, maintaining a minimum distance of 10 meters and a distance of 2.5 meters from the irradiant,   please do not install the lamp directly on the surface of the combustible substance;
The continuous working time of the lamp is not recommended to exceed 10 hours, the interval between continuous start lamps should not be less than 10 minutes, otherwise it will not be able to trigger properly because the bulb overheats to protect;
Use the switch valve closed for not more than 5 minutes, if you need to close the light for a long time, should use the console (lamp gun control channel) to close the lamp gun;
In order to ensure that multiple luminaires better comply with the scene effect, lamps should not always be in the incomplete current scene, that is, to start the next scene action, it is best not to exceed 3 minutes, to ensure that multiple lamps can run synchronously;
During use, if the lamp abnormal should stop using the lamp in time to prevent other failures.
12.Notes on the use of RDM
The RDM is an extended version of the DMX512-A protocol, theRemote DeviceManagementprotocol, and the traditional DMX512 protocol communication is one-way communication, based on the RS-485 bus,RS-485 is a time-sharing multipoint, half-duplex protocol, allowing only one port to be output for the host at the same time, so there are a few things to note when using RDM
To use a console or host device that supports the RDM protocol host;
To use a bidirectional signal amplifier, the traditional one-way signal amplifier does not apply to the RDM protocol because the RMD protocol requires feedback data, and the use of a one-way amplifier blocks the returned data, resulting in a search for luminaires;
All luminaires must be set to DMX mode to ensure that there is only one host on the signal line;
Terminals 2 and 3 of the terminal plug must be inserted between a 120ohm impedance matching resistor, when the signal line is longer, reduce signal reflection will use differential signal more stable, conducive to the quality of communication;