EXTRACTED TEXT FROM: 350三合一说明书(英文版.docx

350W Beam lamp shaking head lamp

Make use of the saying book

 

Read the instructions carefully before useRead the instructions carefully before use
Read the instructions carefully before use

Read the instructions carefully before use

Catalogue
1. Precautions and installation1
1.1 Statement1
1.2 Maintenance1
1.3 Product Precautions1
1.4 Product Introduction1
1.5 Signal Cable connection2
1.6 Lamp Installation2
2 Control Panel4
2.1 Keystroke Instructions4
2.2 Main Menu5
2.2.1 Settings5
2.2.2 Manual5
2.2.3 Information6
2.2.4 Factory7
3 Channel functions8
3.1Channel table8
4 Common faults11


Precautions and installation Precautions and installation
Statement
Thank you for choosing our products!734 This product is in good condition and the package is complete when it leaves the factory.For your safe and effective use of this product, please read this instruction carefully and completely before you use this product.This instruction manual contains important information for installation and use. Please install and operate in accordance with the instructions. At the same time, please keep this instruction manual properly for use at any time.Our company does not assume all responsibility for damage to luminaires or other performance due to individuals not following the instructions during installation, use or maintenance.
This manual is subject to technical changes without prior notice.

Maintenance
Disconnect the power supply before performing maintenance.
The lamp should be kept dry and avoid working in wet environment.
Intermittent use will effectively extend the life of the luminaire.
For good ventilation and lighting, take care to clean the fan and fan net as well as the lens frequently.
Do not rub the light fixture housing with organic solvents such as alcohol to avoid damage.

Product Precautions
This light fixture is for professional use only.
Ensure that the power supply voltage is consistent with the equipment requirements before running.
Do not place this product in a place that is easy to loosen or shake.
In the process of use, if the lamp appears abnormal, it should stop using the lamp in time.
In order to ensure the service life of the product, the product should not be placed in damp or leaking places, but also should not work in the environment where the temperature exceeds 60 degrees.
When the bulb is used, the voltage change of the power supply should not exceed ±10%. If the voltage is too high, the life of the bulb will be shortened. If the voltage is too low, the light color of the bulb will be affected.
After the power off, it takes 20 minutes to use the lamp to cool down fully before it can be used again.
The rotating parts of the lamps and pasting accessories must be checked regularly. If they are loose and shake, they should be reinforced in time to prevent accidents.
In order to ensure the normal use of this product, please read the instructions carefully.

Product Introduction
Power of light source: W;
Voltage: AC 200V~240V/50~60Hz;
Color disk: Each color disk consists of a color plate + white light;
Pattern plate: a pattern effect;
540° translation, 270° tilt.
Overheat protection;
Control mode: DMX512/ master-slave/Automatic;
IP20 protection level

Signal cable connection
Light fixtures feature standard DMX input and output 3-core or 5-core XLR sockets.Use a shielded twisted-pair signal cable designed for DMX 512;The signal line is generally connected at 150 meters, and the DMX512 signal amplifier must be added for long distance signal transmission.
Connect a shielded twisted-pair signal line from the DMX outlet of the controller to the DMX input of the first device, and from the DMX outlet of the first device to the DMX input of the second device, and so on, until all lights have been connected. Then install a terminal plug on the last connected light outlet 3-core jack on each circuit.(Weld a 4/1W, 120Ω resistor between the 2 and 3 pins of the 3-core pin cannon plug).

Important: The wires should not touch each other or the metal housing.


Figure 1 Schematic diagram of DMX signal cable connection
Calculation method of starting address code of luminaire:
The initial address code of the current luminaire is equal to (the initial address code of the previous luminaire)+(the number of channels of the luminaire)
1: Start address code value A001 of the first luminaire.
2: The basic channel number of the controller, should be greater than or equal to the total number of channels used by the lamp.
3: Note: when using any controller, each lamp should have its own initial address code, if the initial address code of the first lamp is set A001, the number of lamp channel pass is 16CH;Then the start of the second lamp address code is set to A017;The initial address code of the third lamp is set to A033;And so on,(this setting also needs to be determined according to different control platforms)

Luminaire installation
Light fixtures can be placed horizontally, slanted, and hung upside down.Be sure to pay attention to the installation method when hanging diagonally and upside down.
As shown in Figure 2, before positioning the lamp, it is necessary to ensure the stability of the installation site. When installing the reverse hanging, it is necessary to ensure that the lamp does not fall down on the support frame. It is necessary to use the safety rope through the support frame and the lamp handle for auxiliary hanging to ensure safety. Prevent the luminaire from falling and sliding.
When installing and debugging the lamps, it is forbidden for pedestrians to pass under them. Regularly check whether the safety rope is worn and whether the hook screws are loose.
Our company does not assume any responsibility for all consequences caused by the fall of the lamp due to the unstable installation of the hanging.

Figure 2. Schematic diagram of the lamp hanging upside down
















Control panel

2.1 Key Instructions





Figure 3 Schematic diagram of key description on the panel
The following takes "Modify DMX address code" as an example to describe the use of keys:
1, if the current is not the main interface, press the "left" key (one or more times) to return to the main interface
2, in the home screen, press the "up" key or "down" key to select the "Settings" button
3. Press the "OK" key to enter the "Settings" interface
4, in the "Settings" interface, press the "up" key or "down" key to select "DMX address"
5, press the "OK" key to enter the editing state
6, press the "up" key or "down" key to modify the DMX address code
7, press the "OK" key to exit the editing state





2.2.1 Settings
Options
Instructions
Running mode
DMX
Slave state: Receives DMX signals from the console or mainframe

Bootstrapping
Host state: Self-actuated and sends DMX signal to slave

Voice control

DMX address
1-512
Press "OK" to enter editing mode.At this point, the hundreds digit is selected, and press the "up" and "down" keys to change the address code.Press the "OK" key again to select the tens edit.Press "OK" once more to select the ones edit.Press again to exit the editing state
Light Bulb
Off
Closing bubble

On
Brightening bubble
Turn on brightening Bubble
Off


On
Light bubbles when you power it on
Motor reset
Off


On
Light fixture reset
Channel mode
Standard 19CH
Extended 24CH
Standard 19 channel mode
Extend the 24 channel mode
Language
Chinese
Set to the Chinese interface

English
Set to the English interface
Screen flip
Off
Front display

On
Screen reverse display
X Inversion
Off


On

Y-reverse
Off


On

XY swap
Off


On
Channel for switching XY axes (including trims)
XY encoder
On
Use an encoder (optocoupler) to judge out of step and automatically correct the position

Off
Correct the position without using an encoder (optocoupler)
DMX signal

Hold
Continue running in its original state

Clear zero
Turn the motor back and stop running
Turn on bright bubble
Off
Direct reset after power on, no light bulb (need to manually light bubbles with menu or console)

On
Automatically light up bubbles after power on, and to wait until the bulb successfully lit up before reset
The color wheel changes linearly
On
The color wheel changes linearly

Off
Color wheel nonlinear change, half color change
Restore default Settings

When you see the confirmation dialog after pressing "OK", press "OK" again to restore the default Settings

2.2.2 Manual control
This interface is used to control the current light fixture (which does not receive DMX signals), corresponding to the channel.Refer to the channel table for details
Options
Instructions
1CH.
0 ~ 255
Press "OK" to enter editing.At this point, the hundreds digit is selected, and press the "up" and "down" keys to change the channel value.Press the "OK" key again to select the tens edit.Press "OK" once more to select the ones edit.Press again to exit the editing state
...
0 ~ 255

15CH.
0 ~ 255

...
0 ~ 255



2.2.3 Information

Options
Instructions
DIS

Display board software version
MT

Motor board software version
Manual
Manual interface
Corresponding channel manual control
Time information
Steps 1 Total brightening bubbles
2. Use in total
Keep track of cumulative brightening bubble times
Record the lighting time
System error

If the red ERR indicator lights up, it indicates that the lamp is running incorrectly. You can enter the sub-interface to check the details.After viewing, you can press the "Clear" button to clear the error record
Blower speed

Displays the current blower speed
Hall XY12
0000
0 when magnetic is detected, 1 otherwise
Hall 3-10
11100010

X-axis codes the disk step value
0000
The number of steps should increase when walking in the forward direction and decrease when walking in the opposite direction.The number should be normal every time you reach the same point
The Y-axis codes the disk step value
0000
The number of steps should increase when walking in the forward direction and decrease when walking in the opposite direction.The number should be normal every time you reach the same point
Permission duration

9999 No encryption;Other values can be used with encryption




A. Error message description

Common error messages
Instructions
MT board connection failed
The motor board is not responding.There is a problem with the serial communication line connecting the display board to the motor board, or there is a problem with the motor board.
X-axis reset failed
There is a problem with the X-axis photoelectric switch, or with the X-axis motor or motor board
Y-axis reset failed
Y-axis photoelectric switch, or Y-axis motor or motor board has a problem
X axis Hall error
X-axis Hall, or there is a problem with the motor board
Y-axis Hall error
Y-axis Hall, or a problem with the motor board
Color plate reset failed
Color disk Hall, or there is a problem with the color disk motor
Pattern disk reset failed
Pattern plate Hall, or pattern plate motor has a problem
The focus reset failed
Focus Hall, or there is a problem with the focusing motor
Bulb control failure
Failure to light or extinguish bubbles, faulty laminator or bulb


2.2.4 Factory
Calibration
X-axis
After entering the sub-interface, you can adjust the reset position of the motor such as X axis and Y axis to make up for the error on the hardware installation. The adjustment range is -128~+127, and +0 indicates no adjustment.

Y-axis


Color


Gobo


Gobo 2


Gobo 2 Rotation


Focus


Zoom 


Dimming


Prism 1 zero


Prism 1 stroke


Prism 2 zeros


Prism 2 stroke


Frost zero


Frost stroke


Prism 1 Rotation


Prism 2 Rotate


Zeroing

Channel function
3.1Channel table
Channels
Channel pattern

19
24
1
X
X
2
Y
Y
3
XY speed
X Fine
4
Dimming
Y Fine
5
Shutter
XY speed
6
Color 
Lamp & Reset
7
Gobo
Color 
8
Gobo 2
Color Fine
9
Gobo 2 Rotation
Gobo
10
Prism 1
Gobo 2
11
Prism 1 Rotate
Gobo 2 Rotation
12
Prism 2
Gobo 2 Rotation Fine
13
Prism 2 Rotate
Prism 1
14
Frost
Prism 1 Rotate
15
Zoom 
Prism 2
16
Focus
Prism 2 Rotate
17
Lamp & Reset
Frost
18
X Fine
Zoom 
19
Y Fine
Zoom Fine
20

Focus
21

Focusing Fine 
22

Shutter
23

Dimming
24

Dimming Fine













Channel parameter values (full version) :
19 Channel mode:
Channel
Features
Channel value
Effects
1
X
000-255.
Horizontal 540 degree scan
2
Y
000-255.
Vertical 270 degree scan
3
XY speed
000-255.
Speed from fast to slow
4
Dimming
000-255.
Dark to light
5
Shutter
000-003.
004-250.
251-255.
Light brake closed
Stroboscopic from slow to fast
Light brake on → (controlled by dimmer channel)
6
Color 
000-004.
005-009
010-014
015-019
020-024
025-029
030-034
035-039
040-044
045-049
050-054
055-059
060-064
065-069
070-074
075-079
080-084
085-089
090-094
095-099
100-104
105-109
110-114
115-119
120-124
125-129
130-134
135-139
140-200
201-255
White light
White light + Color 1
Color 1
Color 1+ Color 2
Color 2
Color 2+ Color 3
Color 3
Color 3+ Color 4
Color 4
Color 4+ Color 5
Color 5
Color 5+ Color 6
Color 6
Color 6+ Color 7
Color 7
Color 7+ Color 8
Color 8
Color 8+ Color 9
Color 9
Color 9+ Color 10
Color 10
Color 10+ Color 11
Color 11
Color 11+ Color 12
Color 12
Color 12+ Color 13
Color 13
Color 13+ white light
Positive flowing water (from fast to slow)
Reverse flow (slow to fast)
7
Gobo
000-004
005-009
010-014
015-019
020-024
025-029
030-034
035-039
040-044
045-049
050-054
055-059
060-064
065-069
070-074
075-079
080-084
085-089
090-094
095-099
100-104
105-109
110-114
115-119
120-124
125-129
130-134
135-139
140-200
201-255
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 6
Gobo 7
Gobo 8
Gobo 9
Gobo 10
Gobo 11
Gobo 12
Gobo 13
Gobo 14
Gobo 15
Gobo 1 Shake(from slow to fast)
Gobo 2 Shake(from slow to fast)
Gobo 3 Shake(from slow to fast)
Gobo 4 Shake(from slow to fast)
Gobo 6 Shake(from slow to fast)
Gobo 7 Shake(from slow to fast)
Gobo 8 Shake(from slow to fast)
Gobo 9 Shake(from slow to fast)
Gobo 10 Shake(from slow to fast)
Gobo 11 Shake(from slow to fast)
Gobo 12 Shake(from slow to fast)
Gobo 13 Shake(from slow to fast)
Gobo 14 Shake(from slow to fast)
Gobo 15 Shake(from slow to fast)
Reverse flowing water (from fast to slow)
Forward flow (slow to fast)
8
Gobo 2
000-009
010-019
020-029
030-039
040-049
050-059
060-069
070-079
080-089
090-099
100-104
105-109
110-114
115-119
120-124
125-129
130-134
135-139
140-144
145-200
201-255
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Gobo 8
Gobo 9
Gobo 10
Gobo 2 Shake (from slow to fast)
Gobo 3 Shake (from slow to fast)
Gobo 4 Shake (from slow to fast)
Gobo 5 Shake (from slow to fast)
Gobo 6 Shake (from slow to fast)
Gobo 7 Shake (from slow to fast)
Gobo 8 Shake (from slow to fast)
Gobo 9 Shake (from slow to fast)
Gobo 10 Shake (from slow to fast)
Reverse flowing water (from fast to slow)
Forward flow (slow to fast)
9
Gobo2 Rotation
000-127.
128-191.
192-255.
Angle adjustment
Reverse fast rotation to slow rotation
Forward slow spin to fast spin
10
Prism 1
000-127.
128-255.
None
Prism 1 Cut in
11
Prism 1 Rotate
000-127.
128-191.
192-255.
Prism Angle adjustment
Reverse rotation (from fast to slow)
Forward rotation (from slow to fast)
12
Prism 2
000-127.
128-255.
None
Prism 2 Cut in
13
Prism 2 Rotate
000-127.
128-191.
192-255.
Prism Angle adjustment
Reverse rotation (from fast to slow)
Forward rotation (from slow to fast)
14
Frost
000-127.
128-255.
Frost
Frost Cut in
15
Zoom 
000-255.
Gobo clarity from far to near
16
Focus
000-255.
Gobo clarity from far to near
17
Lamp & Reset
000-099.
100-105.
106-199.
200-205.
206-250.
251-255.
None
Lamp Off
None
Lamp On
None
Reset All
18
X Fine
000-255.
Horizontal 1.2 degree fine tuning
19
Y Fine 
000-255.
Vertical 1.2 degree fine tuning



24 channel mode:
Channels
Features
Channel value
Effects
1
X
000-255.
Horizontal 540 degree scan
2
Y
000-255.
Vertical 270 degree scan
3
X Fine
000-255.
Horizontal 1.2 degree fine tuning
4
Y Fine
000-255.
Vertical 1.2 degree fine tuning
5
XY speed
000-255.
Speed from fast to slow
6
Lamp & Reset
000-099.
100-105.
106-199.
200-205.
206-250.
251-255.
None
Lamp Off
None
Lamp On
None
Reset All
7
Color 
000-004.
005-009
010-014
015-019
020-024
025-029
030-034
035-039
040-044
045-049
050-054
055-059
060-064
065-069
070-074
075-079
080-084
085-089
090-094
095-099
100-104
105-109
110-114
115-119
120-124
125-129
130-134
135-139
140-200
201-255
White light
White light + Color 1
Color 1
Color 1+ Color 2
Color 2
Color 2+ Color 3
Color 3
Color 3+ Color 4
Color 4
Color 4+ Color 5
Color 5
Color 5+ Color 6
Color 6
Color 6+ Color 7
Color 7
Color 7+ Color 8
Color 8
Color 8+ Color 9
Color 9
Color 9+ Color 10
Color 10
Color 10+ Color 11
Color 11
Color 11+ Color 12
Color 12
Color 12+ Color 13
Color 13
Color 13+ white light
Positive flowing water (from fast to slow)
Reverse flow (slow to fast)
8
Color Fine
000-255.

9
Gobo
000-004
005-009
010-014
015-019
020-024
025-029
030-034
035-039
040-044
045-049
050-054
055-059
060-064
065-069
070-074
075-079
080-084
085-089
090-094
095-099
100-104
105-109
110-114
115-119
120-124
125-129
130-134
135-139
140-200
201-255
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 6
Gobo 7
Gobo 8
Gobo 9
Gobo 10
Gobo 11
Gobo 12
Gobo 13
Gobo 14
Gobo 15
Gobo 1 Shake(from slow to fast)
Gobo 2 Shake(from slow to fast)
Gobo 3 Shake(from slow to fast)
Gobo 4 Shake(from slow to fast)
Gobo 6 Shake(from slow to fast)
Gobo 7 Shake(from slow to fast)
Gobo 8 Shake(from slow to fast)
Gobo 9 Shake(from slow to fast)
Gobo 10 Shake(from slow to fast)
Gobo 11 Shake(from slow to fast)
Gobo 12 Shake(from slow to fast)
Gobo 13 Shake(from slow to fast)
Gobo 14 Shake(from slow to fast)
Gobo 15 Shake(from slow to fast)
Reverse flowing water (from fast to slow)
Forward flow (slow to fast)
10
Gobo 2
000-009
010-019
020-029
030-039
040-049
050-059
060-069
070-079
080-089
090-099
100-104
105-109
110-114
115-119
120-124
125-129
130-134
135-139
140-144
145-200
201-255
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Gobo 8
Gobo 9
Gobo 10
Gobo 2 Shake (from slow to fast)
Gobo 3 Shake (from slow to fast)
Gobo 4 Shake (from slow to fast)
Gobo 5 Shake (from slow to fast)
Gobo 6 Shake (from slow to fast)
Gobo 7 Shake (from slow to fast)
Gobo 8 Shake (from slow to fast)
Gobo 9 Shake (from slow to fast)
Gobo 10 Shake (from slow to fast)
Reverse flowing water (from fast to slow)
Forward flow (slow to fast)
11
Gobo2 Rotation
000-127.
128-191.
192-255.
Angle adjustment
Reverse fast rotation to slow rotation
Forward slow spin to fast spin
12
Gobo2 Rotation Fine 
000-255.

13
Prism 1
000-127.
128-255.
None
Prism 1 Cut in
14
Prism 1 Rotate
000-127.
128-191.
192-255.
Prism Angle adjustment
Reverse rotation (from fast to slow)
Forward rotation (from slow to fast)
15
Prism 2
000-127.
128-255.
None
Prism 2 Cut in
16
Prism 2 Rotate
000-127.
128-191.
192-255.
Prism Angle adjustment
Reverse rotation (from fast to slow)
Forward rotation (from slow to fast)
17
Frost
000-127.
128-255.
None
Frost Cut in
18
Zoom 
000-255.
Gobo clarity from far to near
19
Zoom Fine 
000-255.

20
Focus
000-255.
Gobo clarity from far to near
21
Focus Fine 
000-255.

22
Shutter
000-003.
004-250.
251-255.
Light brake closed
Stroboscopic from slow to fast
Light brake on → (controlled by dimmer channel)
23
Dimming
000-255.
Dark to light
24
Dimming Fine
000-255.




Common faults
According to some common faults, the corresponding solutions are put forward.Any unsolvable problems should be dealt with by professionals.Disconnect the light fixture before maintaining it.
Light bulb is not on
Check that the voltage that matches the light fixture is installed;
Check whether the lamp supply power connection or control switch is in bad contact;
Check if the power supply is insufficient;
Check that the DMX512 controller is sending instructions.

The light fixture does not accept control from the console after normal reset
Check luminaire digital start address value and function options are correct;
Check whether the connection of communication control line is correct, the communication line is too long or has been interrupted;
Check whether the control equipment is invalid, check whether the serial access signal amplifier is invalid;
Check whether the communication line is too long or other equipment interferes with each other;
Optimize wiring, shorten the length of control signal lines, high voltage and low voltage lines separate wiring;
Add signal amplifiers;
Signal line using high-quality shielded twisted pair wire;
Connect the signal terminal resistor (120 ohm) at the end of the lamp.

Luminaire does not start
Check that the power supply parameters are consistent with the lamp;
Check the poor contact caused by extrusion deformation, vibration and moisture of internal parts in the long distance transportation process
Or fall off.
Please check whether the internal wire integration connector of the lamp has fallen off or loosened.
Check whether the electronic components of the lamp (such as electronic transformer, PCB board, motor control board, etc.) are loose, short circuit and burned out.

When working, the action of the X or Y axis of the lamp is not normal
Follow the previous step to check them one by one;
Check whether the transmission belt corresponding to the X and Y axis directions in the lamp falls off and breaks;
Check whether the data feedback receiver (optocoupler) corresponding to the X and Y directions in the lamp is damaged;
Restart the machine and reset it once.