EXTRACTED TEXT FROM: 547C-A423-36颗矩阵灯（青春款）英文说明书.docx

English instruction for 547C-A423-36 matrix lamps (youth models)
First, the display panel

Menu up and down confirmation
Key definition:
Menu key: select function
Up arrow: parameter increment
Down arrow: decreasing parameter
Confirm key: OK and save.
Second, the menu function
Press the menu key after powering on and turning on, and the menu menu will appear in turn; Press the up or down key to modify the function parameters, and press the Enter key to save the current function and parameters (with power-off memory after saving).
Menu menu:
A001

A512
Modify the address code (A001~A512) up or down, and press the Enter key to save. A001 is the default.
C004

C144
Modify channels C004, C12 and C144 up or down, and confirm to save. The default is CH12.
M000

M096
Modify the built-in effect (M000~M096) up or down, and press OK to save. The default value is M000.
S000

S255
Modify the running speed of the built-in effect up or down (S000~S255), press the Enter key to save, and the default value is S010.
R255

R000
Modify the brightness of the red light bulb (R000~ R255) up or down, and press the Enter key to save. R255 is the default.
G255

G000
Modify the brightness of the green light bulb (G000~G255) up or down, and press the Enter key to save. The default value is G255.
B255

B000
Modify the brightness of the blue light bulb (B000~ B255) up or down, and press the Enter key to save. B255 is the default.
W255

W000
Modify the brightness of the white light bulb (B000~ B255) up or down, and press the Enter key to save. B255 is the default.
T000


Display the temperature, such as T045, indicating that the current lamp temperature is 45℃; 10K thermistor display T000 is not installed.

Third, the factory settings
In case of any address code from A001~A512, press the menu key for 5 seconds to enter the factory setting. The factory settings mainly include the functions of lamp output power, fan setting mode, setting temperature protection point and sending parameters. Press the menu button for 5 seconds to exit any mode set by the factory.
Factory Settings Table:
R255

R032
Modify the red bulb current (R032~ R255) up or down, and press the Enter key to save. R220 is the default.
G255

G032
Modify the green bulb current (G032~G255) up or down, and press the Enter key to save. The default value is G220.
B255

B032
Modify the blue bulb current (B032~ B255) up or down, and press the Enter key to save. B220 is the default.
W255

W032
Modify the white bulb current (w032~ w255) up or down, and press the Enter key to save. The default value is w220.
Dir0

Dir7
Modify the direction of running water (d0~ d7) up or down, and confirm to save. d0 is the default.
FAN0

FAN1
Fan setting: start the fan when the light bulb of FAN0 is on, and start the fan when the temperature of FAN1 reaches 40 degrees. Press the Enter key to save.
T040

T070
Set the temperature protection point, modify the parameters (40℃~70℃) up or down, and press the Enter key to save. The default value is T065.
Send

Send
Send the factory setting parameters of this machine up or down to all other lamps with three-core signal lines connected in parallel; Press the menu button for 5 seconds to confirm the sending parameters, and press the confirm button to cancel the sending if the parameters are denied.
Fourth, master-slave control
Two or more identical lamps are connected by DMX three-core signal lines, all lamps are set to any address code A001~A512, and any one is set as the master, while other lamps are slaves, and all slave displays do not flicker; When the master adjusts the gradient, pulse change, voice control and self-propelled effect, all slaves synchronize the gradient, pulse change, voice control and self-propelled effect.
Special attention: 1. Only one host can be set for a group of lamps. If there are multiple hosts, all lamps will flash without synchronization.
2. All lamps and lanterns must be used when the DMX512 console is closed.
V. DMX512 console
Set the address codes of all lamps and lanterns after power-on, and then connect all lamps and lanterns to DMX512 console in parallel with three-core signal lines. The address codes will stop flashing, indicating that DMX512 console signals have been sent to lamps and lanterns, and use DMX512 console to control related functions according to the channel table.
CH04 Channel Table Description:
passage
Channel value
Basic function of channel
one
000-255
R red lamp bead linear dimming
2
000-255
G linear dimming of green lamp beads
three
000-255
B linear dimming of blue lamp beads
four
000-255
W white lamp bead linear dimming
CH12 Channel Table Description:
passage
Channel value
Basic function of channel
one
000-255
Total dimming
2
000-255
stroboscopic
three
000-255
R red lamp bead linear dimming
four
000-255
G linear dimming of green lamp beads
five
000-255
B linear dimming of blue lamp beads
six
000-255
W white lamp bead linear dimming
seven
000-255
Macro color
eight
000-255
model
nine
000-255
speed
10
000-255
direction
11
000-255
background color
twelve
000-255
Background tone light
CH144 channel table description:
passage
Channel value
Basic function of channel
one
000-255
Linear dimming of the first red lamp bead
2
000-255
Linear dimming of the first green lamp bead
three
000-255
Linear dimming of the first blue lamp bead
four
000-255
Linear dimming of the first white lamp bead
…
…
… …
141
000-255
Linear dimming of the 36th red lamp bead
142
000-255
Linear dimming of the 36th green lamp bead
143
000-255
Linear dimming of the 36th blue lamp bead
144
000-255
Linear dimming of the 36th white lamp bead



VII. Technical parameters
Voltage: AC100~240V 50/60HZ
Power: 200W
Lamp beads: 36 8W four-in-one sharp lamp beads.
Control mode: DMX512, self-propelled, master-slave, voice control, RDM.
Channels: select channels CH04, CH12 and CH144.
Dimming: 32bit 0~100% linear dimming
Features: dyeing+flash
Working temperature: -30 ~50℃
Strobe frequency: 1~30HZ
Appearance: metal, black
Connection mode: DMX512 input/output/power input/output.
IP grade: IP20
Size: weight: