1. Remove the packagingTo ensure proper and safe use of this product, please read the instruction manual carefully before installation. This manual contains essential installation and application information. Please strictly follow the operational steps outlined in the manual during installation and operation. Additionally, please keep this manual properly.The 19-channel focus system is engineered and manufactured to CE standards, featuring the internationally compliant DMX512 signal protocol. It supports both standalone and networked control, delivering rapid rotation, low noise, and robust functionality. Ideal for small to medium-sized venues including concerts, theaters, studios, nightclubs, and bars.This product features 19 high-brightness, stable 40W 4-in-1 LEDs. Handle the packaging carefully when removing it. After opening, inspect the product for any damage during transportation and verify that all components are intact.19 staining lines---------1 unit                                   signal line--------1 unit                 Manual------------1 copy                                           Power cord--------------1 piece                               1. Remove the packagingTo ensure proper and safe use of this product, please read the instruction manual carefully before installation. This manual contains essential installation and application information. Please strictly follow the operational steps outlined in the manual during installation and operation. Additionally, please keep this manual properly.The 19-channel focus system is engineered and manufactured to CE standards, featuring the internationally compliant DMX512 signal protocol. It supports both standalone and networked control, delivering rapid rotation, low noise, and robust functionality. Ideal for small to medium-sized venues including concerts, theaters, studios, nightclubs, and bars.This product features 19 high-brightness, stable 40W 4-in-1 LEDs. Handle the packaging carefully when removing it. After opening, inspect the product for any damage during transportation and verify that all components are intact.19 staining lines---------1 unit                                   signal line--------1 unit                 Manual------------1 copy                                           Power cord--------------1 piece                               
1. Remove the packaging
To ensure proper and safe use of this product, please read the instruction manual carefully before installation. This manual contains essential installation and application information. Please strictly follow the operational steps outlined in the manual during installation and operation. Additionally, please keep this manual properly.

The 19-channel focus system is engineered and manufactured to CE standards, featuring the internationally compliant DMX512 signal protocol. It supports both standalone and networked control, delivering rapid rotation, low noise, and robust functionality. Ideal for small to medium-sized venues including concerts, theaters, studios, nightclubs, and bars.

This product features 19 high-brightness, stable 40W 4-in-1 LEDs. Handle the packaging carefully when removing it. After opening, inspect the product for any damage during transportation and verify that all components are intact.

19 staining lines---------1 unit                                   signal line--------1 unit                 
Manual------------1 copy                                           Power cord--------------1 piece                               










1. Remove the packaging
To ensure proper and safe use of this product, please read the instruction manual carefully before installation. This manual contains essential installation and application information. Please strictly follow the operational steps outlined in the manual during installation and operation. Additionally, please keep this manual properly.

The 19-channel focus system is engineered and manufactured to CE standards, featuring the internationally compliant DMX512 signal protocol. It supports both standalone and networked control, delivering rapid rotation, low noise, and robust functionality. Ideal for small to medium-sized venues including concerts, theaters, studios, nightclubs, and bars.

This product features 19 high-brightness, stable 40W 4-in-1 LEDs. Handle the packaging carefully when removing it. After opening, inspect the product for any damage during transportation and verify that all components are intact.

19 staining lines---------1 unit                                   signal line--------1 unit                 
Manual------------1 copy                                           Power cord--------------1 piece                               













                                                     



























2. Remove the packagingSpecificationsVoltage: AC 90–240 V, 50/60 HzTotal Power: 800 WLight Source: 19 pcs 4-in-1 40 W high-brightness LEDsBeam Angle: 4–60°Strobe: 1–25 Hz, with multiple strobe effectsDimming: 0–100% linear dimmingChannels: 4 built-in channel modes: 21 CH / 29 CH / 53 CH / 57 CHControl: DMX512, Auto Run, Sound ActivePan: 540° with 16-bit fine adjustmentTilt: 270° with 16-bit fine adjustmentDisplay: Chinese / EnglishProduct Size: 328 × 252 × 419 mmN.W.: 14 kgCarton Size: 428 × 352 × 519 mm                  2. Remove the packagingSpecificationsVoltage: AC 90–240 V, 50/60 HzTotal Power: 800 WLight Source: 19 pcs 4-in-1 40 W high-brightness LEDsBeam Angle: 4–60°Strobe: 1–25 Hz, with multiple strobe effectsDimming: 0–100% linear dimmingChannels: 4 built-in channel modes: 21 CH / 29 CH / 53 CH / 57 CHControl: DMX512, Auto Run, Sound ActivePan: 540° with 16-bit fine adjustmentTilt: 270° with 16-bit fine adjustmentDisplay: Chinese / EnglishProduct Size: 328 × 252 × 419 mmN.W.: 14 kgCarton Size: 428 × 352 × 519 mm                  
2. Remove the packaging
Specifications
Voltage: AC 90–240 V, 50/60 Hz
Total Power: 800 W
Light Source: 19 pcs 4-in-1 40 W high-brightness LEDs
Beam Angle: 4–60°
Strobe: 1–25 Hz, with multiple strobe effects
Dimming: 0–100% linear dimming
Channels: 4 built-in channel modes: 21 CH / 29 CH / 53 CH / 57 CH
Control: DMX512, Auto Run, Sound Active
Pan: 540° with 16-bit fine adjustment
Tilt: 270° with 16-bit fine adjustment
Display: Chinese / English
Product Size: 328 × 252 × 419 mm
N.W.: 14 kg
Carton Size: 428 × 352 × 519 mm
                  



2. Remove the packaging
Specifications
Voltage: AC 90–240 V, 50/60 Hz
Total Power: 800 W
Light Source: 19 pcs 4-in-1 40 W high-brightness LEDs
Beam Angle: 4–60°
Strobe: 1–25 Hz, with multiple strobe effects
Dimming: 0–100% linear dimming
Channels: 4 built-in channel modes: 21 CH / 29 CH / 53 CH / 57 CH
Control: DMX512, Auto Run, Sound Active
Pan: 540° with 16-bit fine adjustment
Tilt: 270° with 16-bit fine adjustment
Display: Chinese / English
Product Size: 328 × 252 × 419 mm
N.W.: 14 kg
Carton Size: 428 × 352 × 519 mm
                  




Security Noticepay attention to ！Handle with caution. This high-voltage product may cause electric shock if it comes into contact with live wires.This product is in perfect condition before leaving the factory. To maintain its integrity and ensure safe operation, users must follow the safety precautions and warnings in this manual. Important: Damages caused by non-compliance with this manual are not covered by warranty. The supplier shall not be liable for any product issues arising from such non-compliance. If the product has been exposed to extreme temperature fluctuations (e.g., during transportation), do not power it on immediately, as condensation from temperature changes may damage the device. Wait until the product reaches normal temperature before use.This product is designed for indoor use and operates within a voltage range of 90-240V. Ensure the ground voltage does not exceed the product's rated tolerance. The power plug must be inserted into a Class I socket with proper protection. The green or tea-green conductor must be properly grounded.Regularly inspect this product's power cord. Ensure it is not folded, damaged, or scratched, and avoid connecting it to other wires. Exercise special caution when connecting the power cord or related cables. Always unplug the power supply when not in use or before cleaning.Before using the product, familiarize yourself with its operation. Do not let children or non-professionals handle the product.Do not shake this product. Avoid using excessive force during installation or operation. Do not let unqualified personnel operate the product. Most damages are caused by improper operation.The product is not equipped with relevant repair parts. Maintenance and repair of the product can only be performed by professionals!Do not modify this product without authorization, as it may cause damage that is not covered by the warranty. Additionally, improper operation may lead to short circuits, burns, or electric shocks.Security Noticepay attention to ！Handle with caution. This high-voltage product may cause electric shock if it comes into contact with live wires.This product is in perfect condition before leaving the factory. To maintain its integrity and ensure safe operation, users must follow the safety precautions and warnings in this manual. Important: Damages caused by non-compliance with this manual are not covered by warranty. The supplier shall not be liable for any product issues arising from such non-compliance. If the product has been exposed to extreme temperature fluctuations (e.g., during transportation), do not power it on immediately, as condensation from temperature changes may damage the device. Wait until the product reaches normal temperature before use.This product is designed for indoor use and operates within a voltage range of 90-240V. Ensure the ground voltage does not exceed the product's rated tolerance. The power plug must be inserted into a Class I socket with proper protection. The green or tea-green conductor must be properly grounded.Regularly inspect this product's power cord. Ensure it is not folded, damaged, or scratched, and avoid connecting it to other wires. Exercise special caution when connecting the power cord or related cables. Always unplug the power supply when not in use or before cleaning.Before using the product, familiarize yourself with its operation. Do not let children or non-professionals handle the product.Do not shake this product. Avoid using excessive force during installation or operation. Do not let unqualified personnel operate the product. Most damages are caused by improper operation.The product is not equipped with relevant repair parts. Maintenance and repair of the product can only be performed by professionals!Do not modify this product without authorization, as it may cause damage that is not covered by the warranty. Additionally, improper operation may lead to short circuits, burns, or electric shocks.
Security Notice


pay attention to ！
Handle with caution. This high-voltage product may cause electric shock if it comes into contact with live wires.

This product is in perfect condition before leaving the factory. To maintain its integrity and ensure safe operation, users must follow the safety precautions and warnings in this manual. Important: Damages caused by non-compliance with this manual are not covered by warranty. The supplier shall not be liable for any product issues arising from such non-compliance. If the product has been exposed to extreme temperature fluctuations (e.g., during transportation), do not power it on immediately, as condensation from temperature changes may damage the device. Wait until the product reaches normal temperature before use.
This product is designed for indoor use and operates within a voltage range of 90-240V. Ensure the ground voltage does not exceed the product's rated tolerance. The power plug must be inserted into a Class I socket with proper protection. The green or tea-green conductor must be properly grounded.
Regularly inspect this product's power cord. Ensure it is not folded, damaged, or scratched, and avoid connecting it to other wires. Exercise special caution when connecting the power cord or related cables. Always unplug the power supply when not in use or before cleaning.
Before using the product, familiarize yourself with its operation. Do not let children or non-professionals handle the product.
Do not shake this product. Avoid using excessive force during installation or operation. Do not let unqualified personnel operate the product. Most damages are caused by improper operation.
The product is not equipped with relevant repair parts. Maintenance and repair of the product can only be performed by professionals!
Do not modify this product without authorization, as it may cause damage that is not covered by the warranty. Additionally, improper operation may lead to short circuits, burns, or electric shocks.

Security Notice


pay attention to ！
Handle with caution. This high-voltage product may cause electric shock if it comes into contact with live wires.

This product is in perfect condition before leaving the factory. To maintain its integrity and ensure safe operation, users must follow the safety precautions and warnings in this manual. Important: Damages caused by non-compliance with this manual are not covered by warranty. The supplier shall not be liable for any product issues arising from such non-compliance. If the product has been exposed to extreme temperature fluctuations (e.g., during transportation), do not power it on immediately, as condensation from temperature changes may damage the device. Wait until the product reaches normal temperature before use.
This product is designed for indoor use and operates within a voltage range of 90-240V. Ensure the ground voltage does not exceed the product's rated tolerance. The power plug must be inserted into a Class I socket with proper protection. The green or tea-green conductor must be properly grounded.
Regularly inspect this product's power cord. Ensure it is not folded, damaged, or scratched, and avoid connecting it to other wires. Exercise special caution when connecting the power cord or related cables. Always unplug the power supply when not in use or before cleaning.
Before using the product, familiarize yourself with its operation. Do not let children or non-professionals handle the product.
Do not shake this product. Avoid using excessive force during installation or operation. Do not let unqualified personnel operate the product. Most damages are caused by improper operation.
The product is not equipped with relevant repair parts. Maintenance and repair of the product can only be performed by professionals!
Do not modify this product without authorization, as it may cause damage that is not covered by the warranty. Additionally, improper operation may lead to short circuits, burns, or electric shocks.






























4. Operation InstructionsThis product is a shaking dyeing beam lamp designed to create dynamic dyeing effects.Do not start the product immediately after significant temperature changes (e.g., post-transportation), as thermal expansion and contraction may cause damage. Wait until the equipment reaches normal room temperature before initiating operation.--Be cautious of vibrations. Avoid strong impacts during installation.Do not lift the entire product by the lamp head, as this may cause mechanical damage to the device.When selecting an installation location, ensure the product is not exposed to overheating, excessive moisture, or dust. Do not place any wires on the ground, as this may pose an electric shock hazard.--Before installing the product, ensure the installation site is secure--Please secure the product with a safety rope and check all screws during installation--Ensure the lens is in good condition. Replace the lens if it is damaged or scratched.--It is recommended that this product be operated by a technician familiar with it. Non-technical personnel are prohibited from operating this device, as many incidents of loss are caused by improper operation.Store the packaging materials properly for potential secondary transportation.Do not modify the product without the manufacturer or distributor's guidance.Any equipment malfunction caused by improper operation of this device as specified in the instruction manual shall not be covered by warranty. Additionally, any incidents resulting from short circuits, injuries, electric shocks, ultraviolet radiation-induced harm, or bulb explosions shall not be covered by warranty.5. Product Hanging and InstallationNote: For safety, hang and install this product in a location away from walkways, seating areas, or within easy reach.Before hanging this product, ensure the mounting point can support up to 10 times its weight.The product must be equipped with a double protection device, such as a safety rope.Do not stand under the installation point when hanging, removing, or repairing this product.Ensure this product is installed at least 0.5 meters away from flammable materials.Always use safety ropes as a safety measure to prevent accidents caused by loose fasteners.4. Operation InstructionsThis product is a shaking dyeing beam lamp designed to create dynamic dyeing effects.Do not start the product immediately after significant temperature changes (e.g., post-transportation), as thermal expansion and contraction may cause damage. Wait until the equipment reaches normal room temperature before initiating operation.--Be cautious of vibrations. Avoid strong impacts during installation.Do not lift the entire product by the lamp head, as this may cause mechanical damage to the device.When selecting an installation location, ensure the product is not exposed to overheating, excessive moisture, or dust. Do not place any wires on the ground, as this may pose an electric shock hazard.--Before installing the product, ensure the installation site is secure--Please secure the product with a safety rope and check all screws during installation--Ensure the lens is in good condition. Replace the lens if it is damaged or scratched.--It is recommended that this product be operated by a technician familiar with it. Non-technical personnel are prohibited from operating this device, as many incidents of loss are caused by improper operation.Store the packaging materials properly for potential secondary transportation.Do not modify the product without the manufacturer or distributor's guidance.Any equipment malfunction caused by improper operation of this device as specified in the instruction manual shall not be covered by warranty. Additionally, any incidents resulting from short circuits, injuries, electric shocks, ultraviolet radiation-induced harm, or bulb explosions shall not be covered by warranty.5. Product Hanging and InstallationNote: For safety, hang and install this product in a location away from walkways, seating areas, or within easy reach.Before hanging this product, ensure the mounting point can support up to 10 times its weight.The product must be equipped with a double protection device, such as a safety rope.Do not stand under the installation point when hanging, removing, or repairing this product.Ensure this product is installed at least 0.5 meters away from flammable materials.Always use safety ropes as a safety measure to prevent accidents caused by loose fasteners.
4. Operation Instructions

This product is a shaking dyeing beam lamp designed to create dynamic dyeing effects.
Do not start the product immediately after significant temperature changes (e.g., post-transportation), as thermal expansion and contraction may cause damage. Wait until the equipment reaches normal room temperature before initiating operation.
--Be cautious of vibrations. Avoid strong impacts during installation.
Do not lift the entire product by the lamp head, as this may cause mechanical damage to the device.
When selecting an installation location, ensure the product is not exposed to overheating, excessive moisture, or dust. Do not place any wires on the ground, as this may pose an electric shock hazard.
--Before installing the product, ensure the installation site is secure
--Please secure the product with a safety rope and check all screws during installation
--Ensure the lens is in good condition. Replace the lens if it is damaged or scratched.
--It is recommended that this product be operated by a technician familiar with it. Non-technical personnel are prohibited from operating this device, as many incidents of loss are caused by improper operation.
Store the packaging materials properly for potential secondary transportation.
Do not modify the product without the manufacturer or distributor's guidance.
Any equipment malfunction caused by improper operation of this device as specified in the instruction manual shall not be covered by warranty. Additionally, any incidents resulting from short circuits, injuries, electric shocks, ultraviolet radiation-induced harm, or bulb explosions shall not be covered by warranty.

5. Product Hanging and Installation

Note: For safety, hang and install this product in a location away from walkways, seating areas, or within easy reach.
Before hanging this product, ensure the mounting point can support up to 10 times its weight.
The product must be equipped with a double protection device, such as a safety rope.
Do not stand under the installation point when hanging, removing, or repairing this product.
Ensure this product is installed at least 0.5 meters away from flammable materials.
Always use safety ropes as a safety measure to prevent accidents caused by loose fasteners.

4. Operation Instructions

This product is a shaking dyeing beam lamp designed to create dynamic dyeing effects.
Do not start the product immediately after significant temperature changes (e.g., post-transportation), as thermal expansion and contraction may cause damage. Wait until the equipment reaches normal room temperature before initiating operation.
--Be cautious of vibrations. Avoid strong impacts during installation.
Do not lift the entire product by the lamp head, as this may cause mechanical damage to the device.
When selecting an installation location, ensure the product is not exposed to overheating, excessive moisture, or dust. Do not place any wires on the ground, as this may pose an electric shock hazard.
--Before installing the product, ensure the installation site is secure
--Please secure the product with a safety rope and check all screws during installation
--Ensure the lens is in good condition. Replace the lens if it is damaged or scratched.
--It is recommended that this product be operated by a technician familiar with it. Non-technical personnel are prohibited from operating this device, as many incidents of loss are caused by improper operation.
Store the packaging materials properly for potential secondary transportation.
Do not modify the product without the manufacturer or distributor's guidance.
Any equipment malfunction caused by improper operation of this device as specified in the instruction manual shall not be covered by warranty. Additionally, any incidents resulting from short circuits, injuries, electric shocks, ultraviolet radiation-induced harm, or bulb explosions shall not be covered by warranty.

5. Product Hanging and Installation

Note: For safety, hang and install this product in a location away from walkways, seating areas, or within easy reach.
Before hanging this product, ensure the mounting point can support up to 10 times its weight.
The product must be equipped with a double protection device, such as a safety rope.
Do not stand under the installation point when hanging, removing, or repairing this product.
Ensure this product is installed at least 0.5 meters away from flammable materials.
Always use safety ropes as a safety measure to prevent accidents caused by loose fasteners.






























Safety Tip: Top-mounted installations require highly experienced installers who can calculate load-bearing requirements, select appropriate materials, and conduct periodic safety inspections. If you lack this expertise, never attempt installation yourself. Improper handling may lead to serious consequences, including personal injury.Before powering on the product, make sure all required hanging and installation steps are completed.Quick-lock hanging system: This product features a specially designed professional hanging mechanism at the base, including a quick-lock hanging component and a safety rope attachment point (see diagram below).When installing this product on the truss, use the appropriate quick-release lock to secure it at the designated quick-release lock mounting point, and fasten it with M10 screws. For added safety, attach the safety rope to the product's bottom safety rope mounting point and secure it to the truss.Regardless of the hanging method you choose, always use the safety rope. The product features a dedicated safety rope attachment point at the bottom (see the image above). Never attach the safety rope to the handle.Safety Tip: Top-mounted installations require highly experienced installers who can calculate load-bearing requirements, select appropriate materials, and conduct periodic safety inspections. If you lack this expertise, never attempt installation yourself. Improper handling may lead to serious consequences, including personal injury.Before powering on the product, make sure all required hanging and installation steps are completed.Quick-lock hanging system: This product features a specially designed professional hanging mechanism at the base, including a quick-lock hanging component and a safety rope attachment point (see diagram below).When installing this product on the truss, use the appropriate quick-release lock to secure it at the designated quick-release lock mounting point, and fasten it with M10 screws. For added safety, attach the safety rope to the product's bottom safety rope mounting point and secure it to the truss.Regardless of the hanging method you choose, always use the safety rope. The product features a dedicated safety rope attachment point at the bottom (see the image above). Never attach the safety rope to the handle.
Safety Tip: Top-mounted installations require highly experienced installers who can calculate load-bearing requirements, select appropriate materials, and conduct periodic safety inspections. If you lack this expertise, never attempt installation yourself. Improper handling may lead to serious consequences, including personal injury.
Before powering on the product, make sure all required hanging and installation steps are completed.
Quick-lock hanging system: This product features a specially designed professional hanging mechanism at the base, including a quick-lock hanging component and a safety rope attachment point (see diagram below).
When installing this product on the truss, use the appropriate quick-release lock to secure it at the designated quick-release lock mounting point, and fasten it with M10 screws. For added safety, attach the safety rope to the product's bottom safety rope mounting point and secure it to the truss.

Regardless of the hanging method you choose, always use the safety rope. The product features a dedicated safety rope attachment point at the bottom (see the image above). Never attach the safety rope to the handle.






Safety Tip: Top-mounted installations require highly experienced installers who can calculate load-bearing requirements, select appropriate materials, and conduct periodic safety inspections. If you lack this expertise, never attempt installation yourself. Improper handling may lead to serious consequences, including personal injury.
Before powering on the product, make sure all required hanging and installation steps are completed.
Quick-lock hanging system: This product features a specially designed professional hanging mechanism at the base, including a quick-lock hanging component and a safety rope attachment point (see diagram below).
When installing this product on the truss, use the appropriate quick-release lock to secure it at the designated quick-release lock mounting point, and fasten it with M10 screws. For added safety, attach the safety rope to the product's bottom safety rope mounting point and secure it to the truss.

Regardless of the hanging method you choose, always use the safety rope. The product features a dedicated safety rope attachment point at the bottom (see the image above). Never attach the safety rope to the handle.



































6.DMX-512 linkageConnect the male end of the XLR signal cable to the controller's signal output port and the female end to the signal input port on the rear panel of this product. Multiple units can be connected in series. The cable must be three-core, shielded, and equipped with both XLR input and output connectors. Refer to the diagram below.                          The DMX-512 connection requires a terminal (loop connection)During installation, if signal cables are laid over long distances or in noisy environments such as dance halls, using a DMX terminal (circuit connection) is recommended to prevent digital control signal interference caused by electrical noise. The DMX terminal consists of a simple XLR connector with 2 or 3 cores and a 120-ohm resistor. Insert the terminal into the XLR output port of the last product, as shown in the figure below.6.DMX-512 linkageConnect the male end of the XLR signal cable to the controller's signal output port and the female end to the signal input port on the rear panel of this product. Multiple units can be connected in series. The cable must be three-core, shielded, and equipped with both XLR input and output connectors. Refer to the diagram below.                          The DMX-512 connection requires a terminal (loop connection)During installation, if signal cables are laid over long distances or in noisy environments such as dance halls, using a DMX terminal (circuit connection) is recommended to prevent digital control signal interference caused by electrical noise. The DMX terminal consists of a simple XLR connector with 2 or 3 cores and a 120-ohm resistor. Insert the terminal into the XLR output port of the last product, as shown in the figure below.
6.DMX-512 linkage

Connect the male end of the XLR signal cable to the controller's signal output port and the female end to the signal input port on the rear panel of this product. Multiple units can be connected in series. The cable must be three-core, shielded, and equipped with both XLR input and output connectors. Refer to the diagram below.

                          

The DMX-512 connection requires a terminal (loop connection)
During installation, if signal cables are laid over long distances or in noisy environments such as dance halls, using a DMX terminal (circuit connection) is recommended to prevent digital control signal interference caused by electrical noise. The DMX terminal consists of a simple XLR connector with 2 or 3 cores and a 120-ohm resistor. Insert the terminal into the XLR output port of the last product, as shown in the figure below.


6.DMX-512 linkage

Connect the male end of the XLR signal cable to the controller's signal output port and the female end to the signal input port on the rear panel of this product. Multiple units can be connected in series. The cable must be three-core, shielded, and equipped with both XLR input and output connectors. Refer to the diagram below.

                          

The DMX-512 connection requires a terminal (loop connection)
During installation, if signal cables are laid over long distances or in noisy environments such as dance halls, using a DMX terminal (circuit connection) is recommended to prevent digital control signal interference caused by electrical noise. The DMX terminal consists of a simple XLR connector with 2 or 3 cores and a 120-ohm resistor. Insert the terminal into the XLR output port of the last product, as shown in the figure below.































7. Menu
main interface
description
explain
temperature
32℃
The temperature of the light plate is 32°C.
Temperature effect on power:
The power is reduced from 70 degrees.
The power increase only begins when the temperature drops below 68 degrees (excluding 68 degrees).
The power remains constant between 68 and 69 degrees.
Turn off the lamp directly at 85 degrees.

**℃
Temperature detection abnormal
electric fan
whack
1) The fan runs for 15 seconds when turned on
2) The fan activates when the light panel temperature reaches 48°C and stops only when it drops below 45°C.

Keep turning
1) Temperature not detected
2) Communication error
address
001 - 512
Increment or decrement the address code by 1 or 1
signal lamp
blue
DMX signal

red
report an error


primary menu
Sub-menu
Three-level menu/parameters
System Settings
running mode
DMX/Voice/Trailer 1/Trailer 2

channel pattern
21CH/29CH/53CH/57CH

Horizontal Inversion
On/Off

Vertical Reversal
On/Off

Reserve feature

optical coupling error correction
On/Off

signal holding
On/Off

Screen Protector
On/Off

Flip screen
On/Off

Sync updates
On/Off
This feature requires the DMX cable to be unplugged.

language
centre /EN

factory data reset
manual mode
Manual control of channel values
000-255
system calibration
enter password
lamp calibration
system reset
actuator motor reset
Reset the effect panel except XY

scan motor reset
Reset only the XY axis

Reset all motors
Lamp reset
system info
Reduction information
Display specific information

DMX data detection
Display specific DMX detection content

sensor information
Display specific information about optocouplers and Hall effect sensors

Hardware version
Display hardware version

software release
Display software version

◆System Settings

option
explain
running mode
The lamp supports three operating modes: DMX mode, self-driving mode, and voice-controlled mode.

DMX pattern
Console mode, receiving DMX signals, RDM signals

Autopilot Mode 1
The lamp operates automatically according to built-in program 1

Autopilot Mode 2
The lamp operates automatically according to built-in program 2

Voice Mode
When the lamp detects a loud sound, it automatically runs a scene according to the built-in program; otherwise, it maintains the last scene.
channel pattern
Available channel values: 21CH/29CH/53CH/57CH
Horizontal Inversion
Set X-axis rotation direction

close
Not reverse

open
opposite direction
Vertical Reversal
Set Y-axis rotation direction

close
Not reverse

open
opposite direction
Reserve feature
optical coupling error correction
Check if XY is out of sync and correct

close
Failure to correct position after losing track

open
Automatic position correction after loss of step
signal holding
The output status of the lamp when there is no DMX signal

close
No signal detected, so the motor and light source reset to their initial positions and states.

open
No signal detected. Maintain the last frame of DMX data output.
Screen Protector
Screen on time

close
Always on

open
Turn off the screen automatically in static mode
Flip screen
Set the screen orientation

close
Display in reverse

open
Reverse display
Sync updates
Sync the setup or calibration parameters of multiple lights

close
Sync update is disabled.

open
Connect multiple lamps with DMX cables to synchronize information on the calibration interface. (Note: Unplug the DMX signal cable)
language
Switch between Chinese and English menus

centre
the Chinese language

EN
English menu
factory data reset
Lamp parameters return to factory settings

cancel
res sic stantibus

affirm
Restore the lamp to factory settings

◆ manual control
This interface controls the current light. See the channel table for details.
Press OK to enter edit mode. Use the up and down keys to change channel values. Press OK again to save changes and exit edit. Press Exit to exit edit without saving changes.

◆ system calibration
A password "8888" is set here to prevent unauthorized access. Press the "OK" key to verify the password.
option
explain
initial position calibration
After entering the sub-interface, you can adjust the reset positions of motors for X-axis, Y-axis, focus adjustment, and rotation to compensate for hardware installation errors. The adjustment range is 0 to 255, with 127 indicating no adjustment.
white balance CAL
Adjust the power of individual LEDs (1-19) and the total LED output, with a range of 0 to 255, where 255 indicates no adjustment.
calibration of power
Adjust the maximum power of the entire lamp. The range is 0 to 255, with 200 indicating no adjustment.
MIC sensitivity calibration
Adjust the voice sensitivity.
change password
Set the system calibration password.





◆ reset
Press the up or down key to switch between reset modes. Press OK to reset directly.
option
explain
actuator motor reset
focus adjustment, motor reset
scan motor reset
Reset only the XY axis
Reset all motors
Lamp reset

◆ system info
option
explain
Reduction error message
If the red ERR indicator light turns on, the lamp is malfunctioning.
1) MCU1 communication failure (motor and display board communication failure)
2) MCU2 communication failure (communication between motor board and light board failed)
3) X/Y optical coupler error
4) Failed rotation and focus reset
DMX data monitoring
Enter the sub-interface to view channel values numerically. You can navigate through pages.
sensor information
1) Hall:

sensor ：
X/Y optical coupler: XXXX--XXXX
                                                   
Hardware version
Hardware information of the lamp
XX                      .   XX               .   XX                   .XX
Display board version. Motor version. Light board version.

Software version
Lamp software version
XX                         .   XX            .   XX                   .XX
Display board version. Motor version. Light board version.




8. Channel Table
Channel table reference to original BQ channel
21CH
function
DMX numeric value
function
1
stroboflash
0-3
photopigment


4-103
Synchronous Stroboscopic Lighting from Slow to Fast


104-107
opening the light


108-207
Split Frequency Strobismus from Slow to Fast


208-212
opening the light


213-225
slow random stroboscopic


226-238
medium speed random strobe


239-255
fast random strobe
2
aiming
0-255
Linear dimming from dark to bright 0-100%
3
amplify
0-255
Focus range from large to small
4
X axle
0-255
horizontal control
5
X-axis fine-tuning
0-255
level control fine adjustment
6
Y axle
0-255
vertical control
7
Y-axis fine-tuning
0-255
vertical fine-tuning control
8
macro
0-9
NF


10-14
All reset valid for 5 seconds
9
Color Macro
0-9
NF


9-255
Color Macro
10
red
0-255
Red linear dimming from dark to bright 0-100%
11
green
0-255
Linear dimming from dark to bright (0-100%)
12
blue
0-255
Blue linear dimming from dark to light 0-100%
13
white
0-255
White linear dimming from dark to bright 0-100%
14
colour temperature
0-9
NF


10-255
8000K-2500K
15
halo strobismus
0-4
NF


5-250
The frequency of the supplementary light flicker increases from slow to fast.


251-255
NF
16
halo light dimming
0-255
Linear dimming from dark to bright 0-100%
17
Aurora Red
0-255
The halo red gradually dims from dark to bright with linear dimming 0-100%
18
Aurora Green
0-255
The halo green gradually dims from dark to bright with linear dimming 0-100%
19
Aurora Blue
0-255
The halo blue transitions linearly from dark to bright at 0-100%
20
Halo effect
0-51
NF


52-255
Effect 1-47 (one effect per 4 numbers)
21
halo effect speed
0-255
Halo effect speed from slow to fast

29CH
function
DMX numeric value
function
1
stroboflash
0-3
photopigment


4-103
Synchronous Stroboscopic Lighting from Slow to Fast


104-107
opening the light


108-207
Split Frequency Strobismus from Slow to Fast


208-212
opening the light


213-225
slow random stroboscopic


226-238
medium speed random strobe


239-255
fast random strobe
2
aiming
0-255
Linear dimming from dark to bright 0-100%
3
dimming fine adjustment
0-255
Linear dimming from dark to bright 0-1%
4
amplify
0-255
Focus range from large to small
5
X axle
0-255
horizontal control
6
X-axis fine-tuning
0-255
level control fine adjustment
7
Y axle
0-255
vertical control
8
Y-axis fine-tuning
0-255
vertical fine-tuning control
9
macro
0-9
NF


10-14
All reset valid for 5 seconds
10
Color Macro
0-9
NF


9-255
Color Macro
11
red
0-255
Red linear dimming from dark to bright 0-100%
12
Red fine-tuning
0-255
Red fine-tuning: linear dimming from dark to bright (0-1%)
13
green
0-255
Linear dimming from dark to bright (0-100%)
14
Green fine-tuning
0-255
Green fine-tuning for linear dimming from dark to bright (0-1%)
15
blue
0-255
Blue linear dimming from dark to light 0-100%
16
Blue fine-tuning
0-255
Blue fine-tuning: linear dimming from dark to bright (0-1%)
17
white
0-255
White linear dimming from dark to bright 0-100%
18
White fine-tuning
0-255
White fine-tuning: linear dimming from dark to bright (0-1%)
19
colour temperature
0-9
NF


10-255
8000K-2500K
20
effect
0-9
NF


10-255
Effect 1-5 (one effect per 50 numbers)
21
Effect speed
0-63
Static effect


64-158
From fast to slow in the forward direction


159-160
static


161-255
Reverse from slow to fast
22
Effect fade
0-255
Effect duration from longest to shortest
23
halo strobismus
0-4
NF


5-250
The frequency of the supplementary light flicker increases from slow to fast.


251-255
NF
24
halo light dimming
0-255
Linear dimming from dark to bright 0-100%
25
Aurora Red
0-255
The halo red gradually dims from dark to bright with linear dimming 0-100%
26
Aurora Green
0-255
The halo green gradually dims from dark to bright with linear dimming 0-100%
27
Aurora Blue
0-255
The halo blue transitions linearly from dark to bright at 0-100%
28
Halo effect
0-51
NF


52-255
Effect 1-47 (one effect per 4 numbers)
29
halo effect speed
0-255
Halo effect speed from slow to fast

53CH
function
DMX numeric value
function
1
stroboflash
0-3
photopigment


4-103
Synchronous Stroboscopic Lighting from Slow to Fast


104-107
opening the light


108-207
Split Frequency Strobismus from Slow to Fast


208-212
opening the light


213-225
slow random stroboscopic


226-238
medium speed random strobe


239-255
fast random strobe
2
aiming
0-255
Linear dimming from dark to bright 0-100%
3
dimming fine adjustment
0-255
Linear dimming from dark to bright 0-1%
4
amplify
0-255
Focus range from large to small
5
X axle
0-255
horizontal control
6
X-axis fine-tuning
0-255
level control fine adjustment
7
Y axle
0-255
vertical control
8
Y-axis fine-tuning
0-255
vertical fine-tuning control
9
macro
0-9
NF


10-14
All reset valid for 5 seconds
10
Color Macro
0-9
NF


9-255
Color Macro
11
red
0-255
Red linear dimming from dark to bright 0-100%
12
Red fine-tuning
0-255
Red fine-tuning: linear dimming from dark to bright (0-1%)
13
green
0-255
Linear dimming from dark to bright (0-100%)
14
Green fine-tuning
0-255
Green fine-tuning for linear dimming from dark to bright (0-1%)
15
blue
0-255
Blue linear dimming from dark to light 0-100%
16
Blue fine-tuning
0-255
Blue fine-tuning: linear dimming from dark to bright (0-1%)
17
white
0-255
White linear dimming from dark to bright 0-100%
18
White fine-tuning
0-255
White fine-tuning: linear dimming from dark to bright (0-1%)
19
Red 1
0-255
Red 1: Linear dimming from dark to bright (0-100%)
20
Red 1 fine-tuning
0-255
Red 1: Linear dimming from dark to bright (0-1%)
21
Green 1
0-255
Green 1: Linear dimming from dark to bright (0-100%)
22
Green 1 fine-tune
0-255
Green 1: Linear dimming from dark to bright (0-1%)
23
Blue 1
0-255
Blue 1: Linear dimming from dark to light (0-100%)
24
Blue 1 Fine Adjustment
0-255
Blue 1: Linear dimming from dark to bright (0-1%)
25
White 1
0-255
White 1: Linear dimming from dark to bright (0-100%)
26
White 1 fine-tuning
0-255
White 1: Linear dimming from dark to bright (0-1%)
27
Red 2
0-255
Red 2: Linear dimming from dark to bright (0-100%)
28
Red 2 fine-tuning
0-255
Red 2: Linear dimming from dark to bright (0-1%)
29
Green 2
0-255
Green 2: Linear dimming from dark to bright (0-100%)
30
Green 2 Fine-tuning
0-255
Green 2: Linear dimming from dark to bright (0-1%)
31
Blue 2
0-255
Blue 2: Linear dimming from dark to bright (0-100%)
32
Blue 2 Fine-Tune
0-255
Blue 2: Linear dimming from dark to bright (0-1%)
33
White 2
0-255
White 2: Linear dimming from dark to bright (0-100%)
34
White 2 fine-tuning
0-255
Adjust the white 2 from dark to bright with linear dimming 0-1%
35
Red 3
0-255
Red 3: Linear dimming from dark to bright (0-100%)
36
Red 3 fine-tuning
0-255
Red 3: Linear dimming from dark to bright (0-1%)
37
Green 3
0-255
Green 3: Linear dimming from dark to bright (0-100%)
38
Green 3 Fine-tuning
0-255
Green 3: Linear dimming from dark to bright (0-1%)
39
Blue 3
0-255
Blue 3: Linear dimming from dark to bright (0-100%)
40
Blue 3 Fine Adjustment
0-255
Blue 3: Linear dimming from dark to bright (0-1%)
41
White 3
0-255
White 3: Linear dimming from dark to bright (0-100%)
42
White 3 fine-tuning
0-255
White 3: Linear dimming from dark to bright (0-1%)
43
colour temperature
0-9
NF


10-255
8000K-2500K
44
effect
0-9
NF


10-255
Effect 1-5 (one effect per 50 numbers)
45
Effect speed
0-63
Static effect


64-158
From fast to slow in the forward direction


159-160
static


161-255
Reverse from slow to fast
46
Effect fade
0-255
Effect duration from longest to shortest
47
halo strobismus
0-4
NF


5-250
The frequency of the supplementary light flicker increases from slow to fast.


251-255
NF
48
halo light dimming
0-255
Linear dimming from dark to bright 0-100%
49
Aurora Red
0-255
The halo red gradually dims from dark to bright with linear dimming 0-100%
50
Aurora Green
0-255
The halo green gradually dims from dark to bright with linear dimming 0-100%
51
Aurora Blue
0-255
The halo blue transitions linearly from dark to bright at 0-100%
52
Halo effect
0-51
NF


52-255
Effect 1-47 (one effect per 4 numbers)
53
halo effect speed
0-255
Halo effect speed from slow to fast

57CH
function
DMX numeric value
function
1
stroboflash
0-3
photopigment


4-103
Synchronous Stroboscopic Lighting from Slow to Fast


104-107
opening the light


108-207
Split Frequency Strobismus from Slow to Fast


208-212
opening the light


213-225
slow random stroboscopic


226-238
medium speed random strobe


239-255
fast random strobe
2
aiming
0-255
Linear dimming from dark to bright 0-100%
3
dimming fine adjustment
0-255
Linear dimming from dark to bright 0-1%
4
amplify
0-255
Focus range from large to small
5
X axle
0-255
horizontal control
6
X-axis fine-tuning
0-255
level control fine adjustment
7
Y axle
0-255
vertical control
8
Y-axis fine-tuning
0-255
vertical fine-tuning control
9
macro
0-9
NF


10-14
All reset valid for 5 seconds
10
Color Macro
0-9
NF


9-255
Color Macro
11
red
0-255
Red linear dimming from dark to bright 0-100%
12
Red fine-tuning
0-255
Red fine-tuning: linear dimming from dark to bright (0-1%)
13
green
0-255
Linear dimming from dark to bright (0-100%)
14
Green fine-tuning
0-255
Green fine-tuning for linear dimming from dark to bright (0-1%)
15
blue
0-255
Blue linear dimming from dark to light 0-100%
16
Blue fine-tuning
0-255
Blue fine-tuning: linear dimming from dark to bright (0-1%)
17
white
0-255
White linear dimming from dark to bright 0-100%
18
White fine-tuning
0-255
White fine-tuning: linear dimming from dark to bright (0-1%)
19
Red 1
0-255
Red 1: Linear dimming from dark to bright (0-100%)
20
Red 1 fine-tuning
0-255
Red 1: Linear dimming from dark to bright (0-1%)
21
Green 1
0-255
Green 1: Linear dimming from dark to bright (0-100%)
22
Green 1 fine-tune
0-255
Green 1: Linear dimming from dark to bright (0-1%)
23
Blue 1
0-255
Blue 1: Linear dimming from dark to light (0-100%)
24
Blue 1 Fine Adjustment
0-255
Blue 1: Linear dimming from dark to bright (0-1%)
25
White 1
0-255
White 1: Linear dimming from dark to bright (0-100%)
26
White 1 fine-tuning
0-255
White 1: Linear dimming from dark to bright (0-1%)
27
Red 2
0-255
Red 2: Linear dimming from dark to bright (0-100%)
28
Red 2 fine-tuning
0-255
Red 2: Linear dimming from dark to bright (0-1%)
29
Green 2
0-255
Green 2: Linear dimming from dark to bright (0-100%)
30
Green 2 Fine-tuning
0-255
Green 2: Linear dimming from dark to bright (0-1%)
31
Blue 2
0-255
Blue 2: Linear dimming from dark to bright (0-100%)
32
Blue 2 Fine-Tune
0-255
Blue 2: Linear dimming from dark to bright (0-1%)
33
White 2
0-255
White 2: Linear dimming from dark to bright (0-100%)
34
White 2 fine-tuning
0-255
Adjust the white 2 from dark to bright with linear dimming 0-1%
35
Red 3
0-255
Red 3: Linear dimming from dark to bright (0-100%)
36
Red 3 fine-tuning
0-255
Red 3: Linear dimming from dark to bright (0-1%)
37
Green 3
0-255
Green 3: Linear dimming from dark to bright (0-100%)
38
Green 3 Fine-tuning
0-255
Green 3: Linear dimming from dark to bright (0-1%)
39
Blue 3
0-255
Blue 3: Linear dimming from dark to bright (0-100%)
40
Blue 3 Fine Adjustment
0-255
Blue 3: Linear dimming from dark to bright (0-1%)
41
White 3
0-255
White 3: Linear dimming from dark to bright (0-100%)
42
White 3 fine-tuning
0-255
White 3: Linear dimming from dark to bright (0-1%)
43
colour temperature
0-9
NF


10-255
8000K-2500K
44
effect
0-9
NF


10-255
Effect 1-5 (one effect per 50 numbers)
45
Effect speed
0-63
Static effect


64-158
From fast to slow in the forward direction


159-160
static


161-255
Reverse from slow to fast
46
Effect fade
0-255
Effect duration from longest to shortest
47
Effect Background Color
0-255
Effect background color: Linear dimming from dark to light 0-100%
48
Background color
0-255
Effect background color: Linear dimming from dark to light 0-100%
49
Effect Background Color
0-255
Effect background color: Linear dimming from dark to light 0-100%
50
Effect Background White
0-255
Effect: Background white linearly dims from dark to light 0-100%
51
halo strobismus
0-4
NF


5-250
The frequency of the supplementary light flicker increases from slow to fast.


251-255
NF
52
halo light dimming
0-255
Linear dimming from dark to bright 0-100%
53
Aurora Red
0-255
The halo red gradually dims from dark to bright with linear dimming 0-100%
54
Aurora Green
0-255
The halo green gradually dims from dark to bright with linear dimming 0-100%
55
Aurora Blue
0-255
The halo blue transitions linearly from dark to bright at 0-100%
56
Halo effect
0-51
NF


52-255
Effect 1-47 (one effect per 4 numbers)
57
halo effect speed
0-255
Halo effect speed from slow to fast

9. Product Maintenance and Cleaning
When testing this product, please note the following points:
All screws and components of installed products must be securely fastened and rust-free.
The housing, lenses, fasteners, and mounting locations (e.g., ceilings, brackets, trusses, etc.) must remain undistorted.
The moving parts of the machine should not be worn out or rotate unbalance.
The power cord must be free from any damage, including material peeling or scratches.
The installation and use of the product must be performed by trained professional technicians to ensure the elimination of safety hazards.
Note: Please unplug the power cord before product maintenance!!



To maintain optimal product condition and prolong its service life, we recommend routine cleaning.
1. Clean both the external and internal lenses weekly to prevent dust buildup that could reduce the product's light output.
2. Clean the fan every week.
3. Every three months, a certified electrical engineer conducts a thorough circuit inspection to ensure proper connections, preventing aging caused by overheating.
We recommend regular cleaning of the product. Please note that do not use damp or linen cloths, and absolutely avoid using alcohol or solvents for cleaning.