EXTRACTED TEXT FROM: 同发主板960K120段长条频闪英文说明书.doc

960K-120-segment strobe Lamp 

Instruction Manual
             
















Due to ongoing product updates,the content of this manual may differ slightly from the actual product,We appreciate your understanding.

Product catalog
ONE: Display panel button function
TWO: Menu function description
THREE: Channel description
FOUR: Commonly used functions
FIVE: Master-Slave settings
SIX: Technical parameter                    

One:Display panel operation

MENU  UP  DOWN  ENTER

Basic usage:
Menu key(MENU): Select various functions
Upward(UP): Function parameter incremental selection
DOWN(DOWN): Function parameter decrease selection
Confirm(ENTER): Determine the current menu


Two:Menu function
After turning on the power, press the menu key (MENU key) and the following functions will appear in turn, and then Press the confirmation key to confirm.(This order is the order of the new machine. If the lamp has used other modes and saved the mode before the shutdown, the mode before the last shutdown will be displayed after the power-on again)After setting other functions, you also need to press the save button to save, otherwise the effect of setting before shutdown will not appear after the next power-on.
A001A001-A512Address code12CHPassage way Mode12CHPassageway Choose:03CH,09CH, 12CH, 45CH,360CH-512running modeDMX512, voice control, self-propelledE001.Effect ModeE001-E127Effect selection (127 types)P000.Effect SpeedP000-P255UP/DOWN key selection Running speed (P000-P255),ENTER key to save Current running speed.CL00.Effect color selectionCL00-CL2323 color choicesDir0Effect DirectionDir0-dir1Effect direction selectionR255.Manual RedR000-R255Manual red adjustment, use when there is no console UP/DOWN key Adjust the brightness between R000-R255G255.Manual GreenG000-G255Manual green adjustment, use when there is no console UP/DOWN key Adjust the brightness between G000-G255B255.Manual BlueB000-B255Manual blue adjustment, used when there is no console UP/DOWN key Adjust the brightness between B000-B255F000.Manual FlashingF000-F255Use the UP or DOWN key to select the speed of strobeT000.Temperature displayT000-T105Display temperatureAfter the setting is completed, press the OK key to save, and the display will flash when saving.

Three:Channel description
3PassagewayFunctionChannel valueDescribe1Red (R)0-2550-%100 linear dimming2Green(G)0-2550-%100 linear dimming3Blue (B)0-2550-%100 linear dimming

9PassagewayFunctionChannel valueDescribe
1Total Dimming0-2550-%100 linear dimming2Strobe0-9No effect10-255Strobe from slow to fast3Self-walking effect0No effect1-2R3-4G5-6B7-8RG9-10RB11-12GB13-14RGB15-16Gradual change17-18Pulse change19-20jump change21-22Effect1................253-255Effect1174Self-walking Effect speed0-255Speed from slow to fast5Effect Direction Selection0-1280-180 degrees129-255180-360 degrees6Effect Color Selection0-10No effect11-21R22-32G33-43B44-54RG55-65RB66-76GB77-87RGB88-98change199-109change2110-120change3121-131change4132-142change5143-153change6154-164change7165-175change8176-186change9187-197change10198-208change11209-219change12220-230change13231-241change14242-252change15253-255change167Red (R)0-2550-%100 linear dimming8Green (G)0-2550-%100 linear dimming9Blue (B)0-2550-%100 linear dimming


12PassagewayFunctionChannel valueDescribe1Total
dimming0-2550-%100 linear dimming2Strobe0-9No effect10-255Strobe from slow to fast3Number and Letter Effect 10-4No effect5-11012-18119-252..............68-74975-81A82-88B..............250-255Z4Number and Letter Effect 20-4No effect5-11012-18119-252..............68-74975-81A82-88B..............250-255Z5Number and Letter Effect 30-4No effect5-11012-18119-252..............68-74975-81A82-88B..............250-255Z6Self-walking effect0No effect1-2R3-4G5-6B7-8RG9-10RB11-12GB13-14RGB15-16Gradual change17-18Pulse change19-20jump change21-22Effect1................253-255Effect1177Self-walking Effect speed0-255Speed from slow to fast8Effect Direction Selection0-1280-180 degrees129-255180-360 degrees9Effect Color Selection0-10No effect11-21R22-32G33-43B44-54RG55-65RB66-76GB77-87RGB88-98change199-109change2110-120change3121-131change4132-142change5143-153change6154-164change7165-175change8176-186change9187-197change10198-208change11209-219change12220-230change13231-241change14242-252change15253-255change1610Red (R)0-2550-%100 linear dimming11Green (G)0-2550-%100 linear dimming12Blue (B)0-2550-%100 linear dimming


45PassagewayFunctionChannel valueDescribe1R10-2550-%100 linear dimming2G10-2550-%100 linear dimming3B10-2550-%100 linear dimming............43R150-2550-%100 linear dimming44G150-2550-%100 linear dimming45B150-2550-%100 linear dimming


360PassagewayFunctionChannel valueDescribe1R10-2550-%100 linear dimming2G10-2550-%100 linear dimming3B10-2550-%100 linear dimming............358R1200-2550-%100 linear dimming359G1200-2550-%100 linear dimming360B1200-2550-%100 linear dimming

Four:Use of commonly used functions
1. DMX512 control
       After power-on, set the address code. If it is the first unit, set the address code to 001.Connect the DMX512 console with a three-core signal cable, and the digital display tube will stop flashing, indicating that the 512 signal has entered the lamp and the lamp can be controlled. At this time, use the console to control the relevant functions according to the instructions of the channel table.
When there are multiple lamps, just connect the lamp behind with the lamp in front with a signal cable and set the address code. At this time, the lamp behind will stop flashing because the connection of 512 signals, the digital tube display panel will also stop flashing, and then it can be controlled and pulled like the lamp in front.
2.Other functions can be used as long as the relevant functions are pressed through the menu key, (use the UP key or DOWM key to select the corresponding speed)

Five: Master-Slave settings
2 or more identical lamps are connected with a 3-core signal cable. If any host is set to voice-controlled or gradient, pulse change, jump, and other lamps are set in 001 mode, then enter the master-slave mode and the slave machine display does not flash (flashing indicates that the machine has not received the signal, and the connection cable must be checked. ) 
Special attention: Only one host can be set in a group of lamps. If there are multiple hosts, all lamps will flash randomly and not synchronize.

Six:technical parameters
Voltage: AC100~240V 50/60HZ 
Power supply Power: 150W.
Lamp beads: 960 X0.25W5050 lamp beads, 120 zones can be controlled independently
Control mode: DMX512, self-propelled, master-slave function, RDM function.Each group of lamp beads can be controlled by click.
Channel: CH03., CH09.CH12.,CH45 CH360.
Dimming: 32bit 0~100% linear dimming
Features: Dyeing+Flash +Running code point control Lamp
Working temperature: -30 degrees~50 degrees
Strobe frequency: 1~30HZ
Appearance: metal, black
Connection method: DMX512 input and output / power input and output.
IP Level: IP20
Size:                       Weight: